Skip to main navigation Skip to search Skip to main content

山火引发输电线路间隙放电机理与击穿特性综述

Translated title of the contribution: Review on Discharge Mechanism and Breakdown Characteristics of Transmission Line Gap Under Forest Fire Condition
  • 中国电力科学研究院

Research output: Contribution to journal › Article › peer-review

70 Scopus citations

Abstract

The high temperature, high electrical conductivity and ashes of forest fire flames can greatly reduce the insulation strength of high voltage overhead transmission line gaps, and can cause transmission line trip out, and the probability of successful re-closing is very low, this may lead to the serious accidents of transmission line out of operation. In recent years, frequent occurrences of forest fire bring great challenge to the safe and steady operation of the power grid. The discharge mechanism and breakdown characteristics of transmission line gap under forest fire condition are reviewed in this paper. The study status of the transmission line forest fire simulation test platforms, experimental methods, discharge mechanism and breakdown characteristics of AC and DC transmission line gap under forest fire conditions in China and abroad are analyzed. The analysis indicates that some test platforms only consider single influencing factor; the differences and disparity are large for the differences of the simulation tests' dimension, vegetation forms, and experimental methods; the influencing mechanism studies of flame combustion characteristics and products to the gaps' discharge also consider single influencing factor. There is a limitation for the guidance of transmission line trip-out prevention under fire conditions. The systematically study of breakdown characteristics of AC and DC transmission line gaps under forest fire conditions with different dimensions and electrodes, and the single and multi-factor influencing mechanism to the gap discharge study with electric field, flame temperature, conductivity, ashes and particles is suggested.
Translated title of the contributionReview on Discharge Mechanism and Breakdown Characteristics of Transmission Line Gap Under Forest Fire Condition
Original languageChinese
Pages (from-to)622-632
Number of pages11
JournalGaodianya Jishu/High Voltage Engineering
Volume41
Issue number2
DOIs
StatePublished - 28 Feb 2015

Funding

高等学校博士学科点专项科研基金(20120141120027)~~;

Keywords

  • forest fire
  • transmission line
  • gap
  • insulation strength
  • discharge mechanism
  • breakdown characteristics

Indexed by

  • EI
  • Scopus
  • CSCD

Fingerprint

Dive into the research topics of 'Review on Discharge Mechanism and Breakdown Characteristics of Transmission Line Gap Under Forest Fire Condition'. Together they form a unique fingerprint.

Cite this