Skip to main navigation Skip to search Skip to main content

混凝土保湿养护智能闭环控制研究

Translated title of the contribution: Intelligent closed-loop control of concrete moisture levels
  • 樊 启祥
  • , 段 亚辉*
  • , 王 业震
  • , 王 孝海
  • , 杨 思盟
  • , 康 旭升
  • *Corresponding author for this work
  • 中国长江三峡集团有限公司
  • 中国华能集团有限公司

Research output: Contribution to journal › Article › peer-review

10 Scopus citations

Abstract

The concrete moisture content must be maintained after curing.The cement particles in concrete cannot fully hydrate and transform to a stable crystalline form if the concrete is not well hydrated.In addition,moisture loss may result in shrinkage,deformation and cracks,which will affect the structure durability.Concrete specifications and experience have shown that the concrete surface humidity should be no less than 95%during curing.Humidity diffusion theory was used to develop a mathematical model for the concrete moisture conservation with the third type of boundary condition at the surface.Information technology and mechanical control theory were then used to develop an intelligent control method for the concrete moisture conservation.An intelligent control system was then developed to automatically collect the temperature,humidity and wind speed near the concrete surface and to then calculate the concrete surface humidity.The intelligent control system provides real-time feedback warnings and intelligently controls a spray tube which reduces labor costs and ensures the concrete quality.The intelligent control equipment can be flexibly adapted to various large,complex engineering projects.
Translated title of the contributionIntelligent closed-loop control of concrete moisture levels
Original languageChinese
Pages (from-to)671-680
Number of pages10
JournalQinghua Daxue Xuebao/Journal of Tsinghua University
Volume61
Issue number7
DOIs
StatePublished - Jan 2021

Funding

中国三峡建设管理有限公司重点资助项目(JG/18039B,JG/18040B);

Indexed by

  • EI
  • Scopus
  • CSCD

Fingerprint

Dive into the research topics of 'Intelligent closed-loop control of concrete moisture levels'. Together they form a unique fingerprint.

Cite this