Skip to main navigation Skip to search Skip to main content

An Alternating Direction Minimization based denoising method for extracted ion chromatogram

  • Tianjun Li
  • , Long Chen*
  • , Xiliang Lu
  • *Corresponding author for this work
  • Univ Macau

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

Accurate extracted ion chromatograms (XIC or EIC) is of great importance for Liquid chromatography mass spectrometry (LC-MS) based quantitative proteomics. However, current preprocessing methods for XIC mainly focus on removing the peaks of low quality. Such operations are helpful for quantitation, but also contain two potential disadvantages: one is that some valuable information may be lost after the peak removal, and the other is that the retained peak lists are still contain noise. Both of the potential disadvantages may bias the final quantitative results. To solve these problems, we proposed an Alternating Direction Minimization (ADM) based denoising framework for XIC. This framework splits the observed XIC signal into baseline (background), noise and true signal, and the true signal is extracted for further analysis. The advantage of this framework is that the inner relationships over each XIC are considered, for which means that the XIC data is handled in a global way. Also, this framework is not sensitive to the noise type, so that it can be applied to wider applications. We adopted the framework for some sample data for quantitation. The quantitative results are employed to show the performance of XIC denoising. Experimental results confirm that the proposed method provides better and more reliable quantitations.
Original languageEnglish
Article number104138
Number of pages11
JournalChemometrics and Intelligent Laboratory Systems
Volume206
DOIs
StatePublished - 15 Nov 2020

Funding

The authors would thank the anonymous reviewers whose comments will help to improve this article. This work has been supported by Science and Technology Development Fund, Macao S.A.R (Grant Number 097/2015/A3, Grant Number 196/2017/A3), University of Macau RC (Grant Number MYRG2015-00148-FST, Grant Number MYRG2018-00132-FST), and the National Nature Science Foundation of China (Grant Number 61673405).

Indexed by

  • Scopus
  • SCIE

Fingerprint

Dive into the research topics of 'An Alternating Direction Minimization based denoising method for extracted ion chromatogram'. Together they form a unique fingerprint.

Cite this