TY - GEN
T1 - Bolt looseness detection under changing temperature conditions using independent component analysis
AU - Xueduo, Xie
AU - Shoucheng, Zhang
AU - Li, Xiao
AU - Wenzhong, Qu
PY - 2016/7/5
Y1 - 2016/7/5
N2 - Damage detection technology based on guided wave is used widely in structural health monitoring, which relies on comparing response signals with baseline records. However, the temperature variation can also produce large changes in guided wave signals, thereby causing a false alarm of damage detection. In this paper, independent component analysis (ICA) method was developed to process guided wave response signal for separating damage-induced information from coherent interference signal. As a result, the influence of temperature variation could be eliminated in the process of damage localization. In the laboratory, the experiment of bolt looseness damage detection was made in the environment of temperature variation. The collected signals were utilized in damage location estimation after processing by ICA. It showed good result for bolt looseness localization, which indicated that this method is robust to the temperature variation exhibited in damage detection based on guided wave.
AB - Damage detection technology based on guided wave is used widely in structural health monitoring, which relies on comparing response signals with baseline records. However, the temperature variation can also produce large changes in guided wave signals, thereby causing a false alarm of damage detection. In this paper, independent component analysis (ICA) method was developed to process guided wave response signal for separating damage-induced information from coherent interference signal. As a result, the influence of temperature variation could be eliminated in the process of damage localization. In the laboratory, the experiment of bolt looseness damage detection was made in the environment of temperature variation. The collected signals were utilized in damage location estimation after processing by ICA. It showed good result for bolt looseness localization, which indicated that this method is robust to the temperature variation exhibited in damage detection based on guided wave.
KW - Bolts
KW - Guided electromagnetic wave propagation
KW - Independent component analysis
KW - Structural analysis
KW - Structural health monitoring
KW - Temperature
KW - Temperature distribution
KW - Changing temperature
KW - Coherent interference
KW - Damage localization
KW - Detection technology
KW - Independent component analysis(ICA)
KW - Looseness detection
KW - Response signal
KW - Temperature variation
KW - Damage detection
UR - https://openir.whu.edu.cn/AchievementDetail/Scopus_b7e89b8c-0c66-432d-b6bb-8e694667ae46
M3 - Conference contribution
SN - 9781510827936
T3 - Eur. Workshop Struct. Health Monit., EWSHM
SP - 2032
EP - 2041
BT - 8th European Workshop on Structural Health Monitoring, EWSHM 2016
PB - NDT.net
ER -