Skip to main navigation Skip to search Skip to main content

Effects of different breathing techniques on the IVIM-derived quantitative parameters of the normal pancreas

  • Xun Ding
  • , Jia Xu
  • , Jun Zhou
  • , Qingyun Long*
  • , Haibo Xu*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

["Purpose: To prospectively compare the differences in intravoxel incoherent motion (IVIM)-derived quantitative parameters in different anatomic locations of the normal pancreas with different breathing techniques in a healthy population.","Method: Twenty-six volunteers successfully underwent pancreas axial IVIM imaging with a 3.0-T MR system using 11 b-values (from 0 to 1000 sec/mm(2)) with three different breathing techniques: free breath (FB), liver dome scout (LDS), and phase scout (PS). The IVIM-derived quantitative parameters in three anatomic locations (head, body, and tail of the pancreas) were calculated. The intra-, inter-, and short-term consistency of IVIM-derived quantitative parameters were assessed by comparing 95% confidence interval (CI) of limits of agreement (LOA) of difference between measurements and clinical maximum allowed difference using the Bland-Altman method. The Kruskal-Wallis test was used to compare pancreatic IVIM-derived parameters.","Results: In Bland-Altman graph, the maximum values of the 95% CIs of LOAs of D-slow, D-fast, and f were (0.123 +/- 0.022) x 10(-3) mm(2)/sec, (22.093 +/- 4.997) x 10(-3) mm(2)/sec, and (3.942 +/- 0.621)%, and the consistency of D-slow and f was good and that of D-fast was poor overall. The D-slow, D-fast, and f values of normal pancreas were (1.056 +/- 0.121) x 10(-3) mm(2)/sec, (55.755 +/- 13.011) x 10(-3) m( ) /sec, and (26.036 +/- 2.361)%, respectively, and there aren't any breathing technique (P > 0.05) or location (P > 0.05) dependent differences.","Conclusions: Our study shows that IVIM-derived quantitative parameters of the pancreas may not be affected by breathing techniques and anatomic locations. The f and D-slow values have good repeated measurement consistency under different breathing techniques."]
Original languageEnglish
Article number109892
Number of pages7
JournalEuropean Journal of Radiology
Volume143
Early online dateAug 2021
DOIs
StatePublished - Oct 2021

Keywords

  • Pancreas
  • Diffusion
  • Magnetic resonance imaging

Indexed by

  • Scopus
  • SCIE

Fingerprint

Dive into the research topics of 'Effects of different breathing techniques on the IVIM-derived quantitative parameters of the normal pancreas'. Together they form a unique fingerprint.

Cite this