Skip to main navigation Skip to search Skip to main content

Fault Detection for Wind Turbine System Using Fractional Extended Dispersion Entropy and Cumulative Sum Control Chart

  • Kaixuan Shao
  • , Yigang He*
  • , Xiaoyan Liu
  • , Zhikai Xing
  • , Bolun Du
  • *Corresponding author for this work
  • State Grid Corporation of China

Research output: Contribution to journal › Article › peer-review

19 Scopus citations

Abstract

Reliable and quick fault detection is crucial for the wind turbine system (WTS) to detect any potential abnormalities and early faults in time. However, constructing sensitive indicators to reflect the operation state of WTS is still a challenging work. In view of the conceptions of fractional calculus and dispersion entropy (DE), this article proposes a novel indicator called fractional extended DE (FrEDE) to cope with the challenge. Specifically, a connection block with an information factor is first applied to enhance the utilization of information in the raw signals. Moreover, fractional calculus is integrated into entropy calculation to support a constructive interplay in the fault detection of complex WTS. The experiments on simulated data investigate the effect of parameters on FrEDE and verify its ability to detect the dynamic changes of complex system. Finally, FrEDE is further applied to two real-world datasets. Comparative experimental results show that FrEDE is able to accurately differentiate normal between faulty states, and a detection scheme fusing FrEDE and cumulative sum control chart (CUSUM) is accessible to detect abnormal states and provide early failure alarm effectively.
Original languageEnglish
Article number3520809
Number of pages9
JournalIEEE Transactions on Instrumentation and Measurement
Volume71
DOIs
StatePublished - Jan 2022

Funding

This work was supported in part by the National Key Research and Development Plan Both "Smart Grid Technology and Equipment" under Grant 2020YFB0905900 and "Important Scientific Instruments and Equipment Development" under Grant 2016YFF0102200; in part by the National Natural Science Foundation of China under Grant 51977153, Grant 51977161, and Grant 51577046; in part by the Fundamental Research Funds for the Central Universities under Grant 2042021kf0233; in part by the State Key Program of National Natural Science Foundation of China under Grant 51637004; in part by the Equipment Research Project in Advance under Grant 41402040301; in part by the Hubei Province Key Research and Development Plan under Grant 2021BEA162; and in part by the Wuhan Science and Technology Plan Project under Grant 20201G01.

Keywords

  • Entropy
  • Dispersion
  • Vibrations
  • Fault detection
  • Feature extraction
  • Wind turbines
  • Fractional calculus
  • Cumulative sum control chart
  • fault detection
  • fractional extended dispersion entropy (FrEDE)
  • health condition monitoring
  • wind turbine

Indexed by

  • Scopus
  • EI
  • SCIE

Fingerprint

Dive into the research topics of 'Fault Detection for Wind Turbine System Using Fractional Extended Dispersion Entropy and Cumulative Sum Control Chart'. Together they form a unique fingerprint.

Cite this