Abstract

Needle-plate electrode is commonly used in the experiment to simulate the fixed metal protrusion defect, one of the main defect types in Gas Insulated Switchgear (GIS). Needle-plate electrode materials, curvature radius of needle tip, needle-plate spacing, etc will affect the intensity and distribution of the electric field between the needle and plate electrodes, and thus affect the chemical and physical process of SF6 gas discharge decomposition, further influencing the concentration and growth regularity of SF6 decomposition components in gas chamber. This paper carried out SF6 partial discharge (PD) decomposition experiment under different needle-plate electrode spacings, using Gas Chromatography (GC) and Gas Chromatography - mass Spectrometry (GC/MS) for quantitative determination of decomposition components. The results show that the needle-plate electrode spacing affects the concentration of SO2F2 significantly, while has no effect on the content of characteristic components CO2, SOF2 and SO2. The volume fraction of SO2F2 decreases obviously with the increase of needle-plate electrode spacing. The ratio of characteristic components phi(SO2F2+SOF2+SO2)/phi(CO2) decreases constantly with the increase of needle plate electrode spacing, while (SOF2+SO2)/phi(SO2F2) has an opposite tendency, and the increase trend is more and more obvious. Finally, it is further verified that the influence of electrode spacing can be ignored when using the concentration of CO2, SOF2 and SO2 to evaluate GIS equipment internal insulation condition by analyzing the gas generation mean square velocity of characteristic components under different needle-plate electrode spacings.
Original languageEnglish
Number of pages4
Journal2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE)
StatePublished - 19 Sep 2016
EventIEEE International Conference on High Voltage Engineering and Application (ICHVE) - Athens,GREECE, Athens, Greece
Duration: 10 Sep 2018 → 13 Sep 2018

Keywords

  • SF6
  • partial discharge
  • needle-plate electrode spacing
  • decomposition components

Indexed by

  • CPCI-S

Fingerprint

Dive into the research topics of 'Impact of the Needle-plate Electrode Spacing on Decomposition Characteristics of SF6 Induced by PD'. Together they form a unique fingerprint.

Cite this