Abstract
Excessive intake of formaldehyde gas is harmful to human health. Design of fast digital detection of formaldehyde gas is contained in this paper, which take use of sensor for rapid detection of formaldehyde in the air, a data conditioning and acquisition circuit of chang ingnano-amps current provided by the sensor into a suitable voltage after the MAX4072 and OP37 was designed and the voltage would be received by MSP430 at last. This formaldehyde digital detectorcan improve the detection accuracy; it also can determine whether the formaldehyde in the air exceed the body can bear in a short period of time. © (2013) Trans Tech Publications, Switzerland.
| Original language | English |
|---|---|
| Pages (from-to) | 954-957 |
| Journal | SENSORS, MECHATRONICS AND AUTOMATION |
| Volume | 278-280 |
| DOIs | |
| State | Published - 1 Jan 2013 |
| Event | 2012 International Conference on Mechatronics and Control Engineering, ICMCE 2012 - Guangzhou, China, Guangzhou, China Duration: 29 Nov 2012 → 30 Nov 2012 |