Skip to main navigation Skip to search Skip to main content

Phase transfer hollow fiber liquid phase microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental and biological samples

Research output: Contribution to journal › Article › peer-review

33 Scopus citations

Abstract

A new method of phase transfer hollow fiber liquid phase microextraction (PT-HF-LPME) combined with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) has been developed for the determination of trace Co, Pd, Cd and Bi in environmental and biological samples. In PT-HF-LPME, an intermediate solvent (1-butanol) was added into the sample solution to ensure the maximum contact area between the target metal ions and the chelating reagent (8-hydroxyquinoline, 8-HQ), which accelerated the formation of 8-HQ-metal complexes and their subsequent extraction by extraction solvent (toluene). The experimental parameters affecting the extraction efficiency of PT-HF-LPME for the target metals were studied by simplex optimization and orthogonal array design (OAD) experiments. Under the optimized conditions, the enrichment factors for Co, Pd, Cd and Bi were 110, 393, 121 and 111-fold, respectively, the limits of detection (LODs, 3 sigma) ranged from 3.7 to 8.3 ng L-1. The relative standard deviations (RSDs, c=0.5 ng mL(-1), n=7) were 8.7. 6.2, 12.4 and 12.9% for Co, Pd, Cd and Bi, respectively. To validate the accuracy of the proposed method, two Certified Reference Materials of GSBZ50009-88 Environment Water and GBW09103 Human Urine were analyzed, and the results obtained for Cd were in good agreement with the certified values. Finally, the developed method was successfully applied to the analysis of Co, Pd, Cd and Bi in lake water and human urine samples. (C) 2012 Elsevier B.V. All rights reserved.
Original languageEnglish
Pages (from-to)516-523
Number of pages8
JournalTalanta
Volume101
DOIs
StatePublished - 15 Nov 2012

Funding

Financial supports from the Science Fund for Creative Research Groups of NSFC (nos. 20621502, 20921062) are highly acknowledged.

Keywords

  • Phase transfer hollow fiber liquid phase microextraction
  • Trace heavy metals
  • ETV-ICP-MS
  • Environmental water
  • Human urine

Indexed by

  • EI
  • Scopus
  • SCIE

Fingerprint

Dive into the research topics of 'Phase transfer hollow fiber liquid phase microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental and biological samples'. Together they form a unique fingerprint.

Cite this