Skip to main navigation Skip to search Skip to main content

Real-time liquid level detecting setup with CIS

Translated title of the contribution: Real-time liquid level detecting setup with CIS
  • Chen Liang-Cai
  • , Lu Feng-Jie
  • , Ma Dan
  • , Ru Geng-Sheng
  • , Huang Ling
  • Institute of Energy and Power
  • Zhengzhou Railway Board Locomotives Office

Research output: Contribution to journal › Article › peer-review

Abstract

The liquid in transparent cylindrical vessel converges light, and the air above the liquid surface scatters the light. Light intensity through the liquid is much greater than that through the air above the liquid surface in CIS (Contact Image Sensor) fixed on the focus line of the liquid cylinder. The higher the liquid level, the more the number of sensor elements to accept the light with high intense. As a result, the real-time level of liquid can be detected by means of signal processing for sensor elements. This method is simple and reliable when the liquid level varies in the range of the height of CIS. We measured 18 liquid levels with approximate equal interval in 200 mm range. Experiment result shows that the mean level error is 0.185 mm and the maximum level error is 0.66 mm.
Translated title of the contributionReal-time liquid level detecting setup with CIS
Original languageChinese
Pages (from-to)71-74
Number of pages4
JournalGuangdian Gongcheng/Opto-Electronic Engineering
Volume32
Issue number12
StatePublished - Jan 2005

Indexed by

  • Scopus

Fingerprint

Dive into the research topics of 'Real-time liquid level detecting setup with CIS'. Together they form a unique fingerprint.

Cite this