Abstract
The experiments on the side connection joint of steel beam and concrete column are simulated by finite element software(ANSYS). The damage character, hysteresis and ductility performance and skeleton curve of experiment and finite element results are comparative analysis. The results show that the joint is strong joint, the design of the joint is fit for the design principle of " strong column and weak beam ". For the results of finite element and experiment coincide, the non-linear finite element model can predict the seismic performance of such kinds of joint accurately.
| Translated title of the contribution | Research on the aseismic behavior of the penetrating column joint of reinforced concrete column and steel beam |
|---|---|
| Original language | Chinese |
| Pages (from-to) | 48-51 |
| Number of pages | 4 |
| Journal | Wuhan Ligong Daxue Xuebao/Journal of Wuhan University of Technology |
| Volume | 31 |
| Issue number | 10 |
| State | Published - Jan 2009 |
Indexed by
- Scopus
Fingerprint
Dive into the research topics of 'Research on the aseismic behavior of the penetrating column joint of reinforced concrete column and steel beam'. Together they form a unique fingerprint.Cite this