Abstract
Up to now, expressions for the diffusion current are known analytically for only very limited electrode geometries, namely spherical and disk electrodes. For more complicated geometries, such as a rectangle, triangle, etc., it is very difficult to derive a rigorous expression for the diffusion-limited current. In view of this situation, it would be useful to seek any universal quantitative relations for microelectrodes of arbitrary geometry. In this paper, a mathematical discussion is presented, proving that the diffusion current at a microelectrode of given geometry should be proportional to the square root of the electrode area.
| Original language | English |
|---|---|
| Pages (from-to) | 289-292 |
| Number of pages | 4 |
| Journal | JOURNAL OF ELECTROANALYTICAL CHEMISTRY |
| Volume | 294 |
| Issue number | 1-2 |
| DOIs | |
| State | Published - 9 Nov 1990 |
Indexed by
- EI
- Scopus
Fingerprint
Dive into the research topics of 'Square root law for the diffusion current at a microelectrode'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver