Skip to main navigation Skip to search Skip to main content

System structure and calibration models of intelligent photogrammetron

  • Heping Pan
  • , Chunsen Zhang

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

This paper describes the structure, geometric model and geometric calibration of Photogrammetron I—the first type of photogrammetron which is designed to be a coherent stereo photogrammetric system in which two cameras are mounted on a physical base but driven by an intelligent agent architecture. The system calibration is divided into two parts: the in-lab calibration determines the fixed parameters in advance of system operation, and the in-situ calibration keeps tracking the free parameters in real-time during the system operation. In a video surveillance set-up, prepared control points are tracked in stereo image sequences, so that the free parameters of the system can be continuously updated through iterative bundle adjustment and Kalman filtering. © 2003 Taylor & Francis Group, LLC.
Original languageEnglish
Pages (from-to)48-54
Number of pages7
JournalGeo-Spatial Information Science
Volume6
Issue number2
DOIs
StatePublished - Jan 2003