Time-frequency domain analysis of conducted EMI caused by disconnect switch operation based on WVD

Translated title of the contribution: Time-frequency domain analysis of conducted EMI caused by disconnect switch operation based on WVD
  • Tao Jinsong
  • , Chen Shixiu

Research output: Contribution to journal › Article › peer-review

Abstract

Along with more and more electronic devices are installed in control room inside and outside of substation, and in the same electromagnetic environment with power system, they will face potential menace of the high frequency (HF) electromagnetic disturbance caused by switch operation, fault and lightening. And disconnect switches operation is a most frequent process in switchyard and substation relative to lightening and fault. Those disturbances can access to the electronic controlling circuit and measurement devices through conducting and coupling methods. If these devices have not reliably protected, potential mangle and destroy should happened and safety running of power system cannot be guaranteed. In this paper disconnect switch operation experiments have been given in 220 kV air-insulated substation, the conducted signals of electromagnetic interference have been obtained from potential transformer (PT) and capacitance voltage transformer (CVT) and primary analysis has been given. In order to find out the relationship of time-frequency domain and signal energy, Wigner-Ville Distribution (WVD) is used to further analysis. Analysis demonstrate that no matter in time domain or frequency domain, the conducted interference of disconnect switch operation get together in a comparatively narrow region according to 40 micro-bursts at 20 times switch operation. The duration of microbursts is not longer than 15.7 μs in time domain and 2.5 MHz in frequency domain. The dominant frequency of the wave also accumulates in small scopes; say 0.7 MHz to 1.45 MHz. The energy have concentrated in a relatively narrow area, less than 2.4 MHz. The results reveal that the dominant frequency of the interference signal is mainly connected with configuration and parameters of the equipments of the substation, other than disconnect switch operation time and speed. It is possible to filter the energy of high frequency caused by disconnect switch or breaker operation. If filter of this frequency scope can be used, it will do well to the secondary equipment.
Translated title of the contributionTime-frequency domain analysis of conducted EMI caused by disconnect switch operation based on WVD
Original languageChinese
Pages (from-to)47-50
Number of pages4
JournalGaodianya Jishu/High Voltage Engineering
Volume32
Issue number4
StatePublished - Jan 2006

Indexed by

  • Scopus

Fingerprint

Dive into the research topics of 'Time-frequency domain analysis of conducted EMI caused by disconnect switch operation based on WVD'. Together they form a unique fingerprint.

Cite this