TY - JOUR
T1 - WD-PINN-based remaining life prediction method for dry-type transformers
AU - Dong, Yu
AU - Wang, Youhang
AU - Li, Zhiqiang
AU - Lei, Ning
AU - Jiang, Hong
AU - Wei, Wei
AU - Li, Yongwen
AU - Wei, Yanchen
PY - 2026/1
Y1 - 2026/1
N2 - Power transformers are pivotal assets in power systems, and accurate prediction of their remaining useful life (RUL) is essential for ensuring safe and stable grid operation. Conventional approaches, including physics based Arrhenius models and data driven machine learning methods, each face inherent limitations. To overcome these chal-lenges, this paper proposes an enhanced physics-informed neural network for dry-type transformer RUL prediction, referred to as WD-PINN (weak-form and dynamically weighted PINN).An engineering-corrected lifetime model is first constructed as the supervisory signal. By applying a multiplicative correction framework, the method generates RUL labels that alleviate the scarcity of authentic failure data. WD-PINN improves upon the conventional PINN architecture through two major advancements. The incorporation of a weak-form conservation consistency constraint transforms point-wise differential requirements into integral expressions, thereby reducing sensi-tivity to higher-order derivatives and measurement noise while enhancing numerical stability under complex operating conditions, including temperature spikes and sudden load variations. In addition, a dynamic weighting mechanism is introduced to auto-matically adjust the balance between data-fitting and physics-based losses. This mechanism prioritizes data fidelity during steady states and strengthens physical con-sistency during regime transitions, enabling effective optimization across diverse op-erating scenarios. Experiments using nearly 10 years of operational data from dry-type transformers demonstrate the superiority of WD-PINN. The model achieves signifi-cantly reduced prediction error, with a mean absolute error (MAE) of 2.5 years, a root-mean-square error (RMSE) of 3.2 years, a mean absolute percentage error (MAPE) of 3.7%, and a coefficient of determination (R2) of 0.98. It remains robust under extreme conditions and consistently outperforms tra-ditional models, while ablation studies confirm the contribution of each component. Overall, the proposed approach delivers high-accuracy, highly adaptive, and robust RUL prediction without compromising physical interpretability, providing a reliable and practical tool for transformer condition assessment. Beyond standalone prediction, the RUL output can serve as an informative input to higher-level grid management and control systems. By integrating the predicted degradation trajectory with coordinated voltage-power control strategies or load redistribution mechanisms, grid operators can proactively adjust operating setpoints before critical ageing thresholds are reached. Such a prediction–control closed-loop framework enables smoother response to sudden load variations and enhances overall system reliability in intelligent power grids. Copyright © 2026 Dong, Wang, Li, Lei, Jiang, Wei, Li and Wei.
AB - Power transformers are pivotal assets in power systems, and accurate prediction of their remaining useful life (RUL) is essential for ensuring safe and stable grid operation. Conventional approaches, including physics based Arrhenius models and data driven machine learning methods, each face inherent limitations. To overcome these chal-lenges, this paper proposes an enhanced physics-informed neural network for dry-type transformer RUL prediction, referred to as WD-PINN (weak-form and dynamically weighted PINN).An engineering-corrected lifetime model is first constructed as the supervisory signal. By applying a multiplicative correction framework, the method generates RUL labels that alleviate the scarcity of authentic failure data. WD-PINN improves upon the conventional PINN architecture through two major advancements. The incorporation of a weak-form conservation consistency constraint transforms point-wise differential requirements into integral expressions, thereby reducing sensi-tivity to higher-order derivatives and measurement noise while enhancing numerical stability under complex operating conditions, including temperature spikes and sudden load variations. In addition, a dynamic weighting mechanism is introduced to auto-matically adjust the balance between data-fitting and physics-based losses. This mechanism prioritizes data fidelity during steady states and strengthens physical con-sistency during regime transitions, enabling effective optimization across diverse op-erating scenarios. Experiments using nearly 10 years of operational data from dry-type transformers demonstrate the superiority of WD-PINN. The model achieves signifi-cantly reduced prediction error, with a mean absolute error (MAE) of 2.5 years, a root-mean-square error (RMSE) of 3.2 years, a mean absolute percentage error (MAPE) of 3.7%, and a coefficient of determination (R2) of 0.98. It remains robust under extreme conditions and consistently outperforms tra-ditional models, while ablation studies confirm the contribution of each component. Overall, the proposed approach delivers high-accuracy, highly adaptive, and robust RUL prediction without compromising physical interpretability, providing a reliable and practical tool for transformer condition assessment. Beyond standalone prediction, the RUL output can serve as an informative input to higher-level grid management and control systems. By integrating the predicted degradation trajectory with coordinated voltage-power control strategies or load redistribution mechanisms, grid operators can proactively adjust operating setpoints before critical ageing thresholds are reached. Such a prediction–control closed-loop framework enables smoother response to sudden load variations and enhances overall system reliability in intelligent power grids. Copyright © 2026 Dong, Wang, Li, Lei, Jiang, Wei, Li and Wei.
KW - Ablation
KW - Couplings
KW - Data reduction
KW - Dynamics
KW - Errors
KW - Forecasting
KW - Learning systems
KW - Machine learning
KW - Mean square error
KW - Neural networks
KW - Power transformers
KW - Robustness (control systems)
KW - Spurious signal noise
KW - Transmissions
KW - Consistency constraints
KW - Dry-type transformer
KW - Dynamic weighting mechanism
KW - Multi-stress coupling
KW - PINN
KW - Remaining useful lives
KW - Robustness
KW - Stress coupling
KW - Weak form
KW - Weak-form and dynamically weighted PINN
KW - Weak-form conservation consistency constraint
KW - Copyrights
KW - dry-type transformer
KW - dynamic weighting mechanism
KW - multi-stress coupling
KW - robustness
KW - RUL
KW - WD-PINN
KW - weak-form conservation consistency constraints
UR - https://openir.whu.edu.cn/AchievementDetail/Scopus_1144b4e0-8563-46e0-8cf7-9e25d3da0101
U2 - 10.3389/fenrg.2026.1768075
DO - 10.3389/fenrg.2026.1768075
M3 - Article
SN - 2296-598X
VL - 14
JO - FRONTIERS IN ENERGY RESEARCH
JF - FRONTIERS IN ENERGY RESEARCH
M1 - 1768075
ER -