跳到主要导航 跳到搜索 跳到主要内容

Direct determination of trace impurities in high purity neodymium after in-situ analyte-matrix separation by fluorination assisted ETV-ICP-AES

  • WJ Ruth
  • , B Hu
  • , M He
  • , ZC Jiang*
  • , YL Wu
  • *此作品的通讯作者

科研成果: 期刊稿件 › 论文 › 同行评审

摘要

Using PTFE as a chemical modifier, a method for the determination of trace impurities in high purity Nd2O3 by in-situ separation and electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry (ETV-ICP-AES) was developed. The analyte-matrix separation and the temperature program of graphite furnace were investigated and optimized. The solid samples were directly introduced into graphite furnace in the form of slurry, where selective volatilization between the matrix and the analytes took place. The Nd matrix was retained in the graphite furnace during the evaporation step, while the trace analyte impurities were vaporized and removed. As a result, the matrix interference that is serious without the modifier is suppressed effectively. The achievable detection limits are (mug (.) g(-1)) : Ti 0.15, Mir 0.15, Ni 0.20, Co 0.54, respectively. The proposed method was applied to direct determination of trace impurities in high purity Nd2O3 with satisfactory results.
源语言英语
页(从-至)319-322
页数4
期刊Journal of Rare Earths
卷22
期3
出版状态已出版 - 6月 2004

关键词

  • chemical analysis
  • fluorination
  • ETV-ICP-AES
  • in-situ separation
  • rare earths

收录

  • SCIE

学术指纹

探究 'Direct determination of trace impurities in high purity neodymium after in-situ analyte-matrix separation by fluorination assisted ETV-ICP-AES' 的科研主题。它们共同构成独一无二的学术指纹。

引用此