摘要
In this paper, three different modeling ranges were selected in the structural analysis for a hydropower house. The analysis was carried out using ABAQUS 6.6. The modeling range has a remarkable effect on finite element method (FEM) calculation result at the middle position of typical cross-sections where the concrete is relatively thin, and at the region close to turbine floor. If the ventilation barrel, floor slabs and columns above turbine floor are excluded from FEM model, the maximum rise difference of pedestal structure increases by about 24% compared with that of the whole model. It is indicated that different modeling ranges indeed affect FEM calculation result, and the structure above turbine floor in the FEM model should be included. © Tianjin University and Springer-Verlag 2009.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 388.0-392.0 |
| 页数 | 5 |
| 期刊 | Transactions of Tianjin University |
| 卷 | 15 |
| 期 | 5 |
| DOI | |
| 出版状态 | 已出版 - 10月 2009 |
关键词
- Finite element method
收录
- EI
- Scopus
学术指纹
探究 'Effect of modeling range on structural analysis for powerhouse of hydroelectric power plant by FEM' 的科研主题。它们共同构成独一无二的学术指纹。引用此