跳到主要导航 跳到搜索 跳到主要内容

Experimental study on seismic performance of hybrid steel-polypropylene fiber-reinforced recycled aggregate concrete-filled circular steel tube columns

科研成果: 期刊稿件 › 论文 › 同行评审

36 引用 (Scopus)

摘要

In this paper, 1 recycled aggregate concrete-filled circular steel tube column (RACFST) and 11 hybrid steel -polypropylene fiber-reinforced recycled aggregate concrete-filled circular steel tube (HFRACFST) columns were designed given the variables of steel fiber (SF) volume content (Vsf = 0.6 %,1.2 %,1.8 %), polypropylene fiber (PPF) content fractions (Vpf = 0.05 %,0.10 %,0.15 %), concrete strengths (C40, C50, C60), thickness of steel tube (t = 2.70 mm, 3.65 mm, 4.50 mm), axial compression ratios (n = 0.25, 0.35, 0.45). Then the influence of variables on hysteretic curves, ductility, energy dissipation and stiffness degradation were studied experimen-tally using the pseudo-static tests. Subsequently, the restoring force models of HFRACFST were proposed based on the experimental results. The results indicated that: (1) The incorporation of HF (hybrid steel-polypropylene fiber) could enhance the hysteretic behaviour of HFRACFST columns. An increase in PPF content had little effect on the lateral bearing capacity and energy dissipation capability. Nevertheless, it could improve the ductility to some extent. As the SF content increased, the lateral bearing capacity, energy dissipation capability and ductility of the specimens increased. (2) An increase in concrete strength resulted in the increase of the bearing capacity and energy dissipation capability, but led to inferior ultimate deformation and ductility. (3) The comprehensive hysteretic behaviour was improved significantly as the thickness of steel tube increased, especially in the energy dissipation capability. (4) The specimens with higher axial compression ratio experienced inferior ultimate deformation and ductility. (5) The ductility indexes of all specimens were higher than 3.0. The yielding elastic and ultimate elastoplastic drift ratios were in the ranges 0.012-0.013 and 0.038-0.054, respectively. The hys-teretic performance of HFRACFST columns could satisfy the requirement of seismic design. It is feasible to apply the HFRACFST columns to vertical load-bearing structures in the seismic zones.
源语言英语
期刊论文编号129418
页数18
期刊Construction and Building Materials
卷359
早期在线日期10月 2022
DOI
出版状态已出版 - 12 12月 2022

基金资助

This study was supported by Natural Science Foundation of China (No.51678456) , Special Project on Technical Innovation of Hubei (No.2019ACA142) .

关键词

  • Steel-polypropylene hybrid fiber
  • Recycled aggregate concrete filled square steel
  • tube
  • Hysteretic performance
  • Pseudo-static test
  • Restoring force model

收录

  • Scopus
  • EI
  • SCIE

学术指纹

探究 'Experimental study on seismic performance of hybrid steel-polypropylene fiber-reinforced recycled aggregate concrete-filled circular steel tube columns' 的科研主题。它们共同构成独一无二的学术指纹。

引用此