@inproceedings{1a7c45e0ccb14b97a454054a8845dfbe,
title = "Maximum size of loop area of a printed circuit board in lightning electromagnetic interference",
abstract = "This paper presented the maximum size (S-max) of printed circuit board (PCB) loop area of a microelectronic equipment with or without iron-network shield that, if the integrated circuits are installed in the board, would not cause to malfunction by lighting current. The value is compared with the lowest magnetic flux density 0.07Ga by which the electronic equipment will be interfered given in paper of R. D. Hill. The results show the relation between the maximum loop area and the distance (d) from lightning channel to the equipment. The S-max is 96cm(2) if the equipment with shield of iron net would not be interfered in operation assuming I - 100kA (amplitude of lightning current), d = 10m. When the equipment is not shielded, even the distance from lightning channel to microelectronic equipment is 1km, else equipment is probably caused to malfunction.",
keywords = "lightning current, electromagnetic induction, microcircuit, noise margin",
author = "WJ Zhou",
year = "1997",
month = jan,
language = "English",
isbn = "7-80003-389-9",
series = "Maximum size of loop area of a printed circuit board in lightning electromagnetic interference",
publisher = "INT ACADEMIC PUBL",
pages = "304--306",
booktitle = "ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS (ICEF '96)",
}