摘要
Firstly, the limitations and advantages of various existing time synchronization solutions of GPS/INS are investigated in this paper. From the angle of modularity, a flexible low-cost time synchronization solution using a DAQ card and Labview software of NI in the way of both hardware and software is proposed and implemented. The test shows that a synchronization accuracy of 5 ms was achieved when the test system was applied to synchronize a low-grade micro-electromechanical inertial measurement unit (IMU), which only has an RS-232 data output interface.
| 投稿的翻译标题 | Modulari practice of time synchronization in integrated GPS/INS systems |
|---|---|
| 源语言 | 中文 |
| 页(从-至) | 830-832+836 |
| 期刊 | Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University |
| 卷 | 35 |
| 期 | 7 |
| 出版状态 | 已出版 - 7月 2010 |