TY - GEN
T1 - Numerical Simulation of Transient Temperature Rise on 110 kV/40 MVA Vehicle-Mounted Mobile Transformer
AU - Feng, Zhijia
AU - Cao, Jinxin
AU - Zhou, Hongling
AU - Tang, Zhenpeng
AU - Wang, Jianguo
AU - Fan, Yadong
AU - Cai, Li
AU - Zhou, Mi
PY - 2023/1
Y1 - 2023/1
N2 - Vehicle-mounted mobile transformers are installed on mobile platforms, characterized by their compact structure and convenient transportation. It can be used as a temporary transformer when the capacity of the main transformer in a substation is insufficient or the power planning and construction do not meet the requirements. In order to analyze the temperature distribution in the compacted 110 kV/40 MVA mobile transformer at this voltage and capacity level, a single-phase axisymmetric 2-D finite element model of the mobile transformer was established, and transient temperature rise of the transformer was simulated using the short-circuit method. The results show that the maximum hotspot temperature reached 87.9 ℃ when the total losses were applied, while it reached 85.2 ℃ when the rated current was applied. The temperature rise satisfies the conditions for safe operation, indicating that the transformer’s structural design is reasonable and has good heat dissipation performance. © Beijing Paike Culture Commu. Co., Ltd 2024.
AB - Vehicle-mounted mobile transformers are installed on mobile platforms, characterized by their compact structure and convenient transportation. It can be used as a temporary transformer when the capacity of the main transformer in a substation is insufficient or the power planning and construction do not meet the requirements. In order to analyze the temperature distribution in the compacted 110 kV/40 MVA mobile transformer at this voltage and capacity level, a single-phase axisymmetric 2-D finite element model of the mobile transformer was established, and transient temperature rise of the transformer was simulated using the short-circuit method. The results show that the maximum hotspot temperature reached 87.9 ℃ when the total losses were applied, while it reached 85.2 ℃ when the rated current was applied. The temperature rise satisfies the conditions for safe operation, indicating that the transformer’s structural design is reasonable and has good heat dissipation performance. © Beijing Paike Culture Commu. Co., Ltd 2024.
KW - Structural design
UR - https://openir.whu.edu.cn/AchievementDetail/EI_1c00f3b4-8184-4107-a273-b72f71a0b6e1
U2 - 10.1007/978-981-99-7413-9_58
DO - 10.1007/978-981-99-7413-9_58
M3 - Conference contribution
SN - 9783032147417
SN - 9789819540440
SN - 9789819540488
SN - 9789819542734
SN - 9789819600571
SN - 9789819637577
SN - 9789819644292
SN - 9789819658473
SN - 9789819663392
SN - 9789819680023
T3 - Lect. Notes Electr. Eng.
SP - 603
EP - 611
BT - Lecture Notes in Electrical Engineering
PB - Springer Science and Business Media Deutschland GmbH
ER -