跳到主要导航 跳到搜索 跳到主要内容

Preparation of polydimethylsiloxane/β-cyclodextrin/divinylbenzene coated "dumbbell-shaped" stir bar and its application to the analysis of polycyclic aromatic hydrocarbons and polycyclic aromatic sulfur heterocycles compounds in lake water and soil by high performance liquid chromatography

  • Chunhe Yu
  • , Zhimin Yao
  • , Bin Hu*
  • *此作品的通讯作者

科研成果: 期刊稿件 › 论文 › 同行评审

104 引用 (Scopus)

摘要

A "dumbbell-shaped" stir bar was proposed to prevent the friction less of coating during the stirring process, and thus prolonged the lifetime of stir bars. The effects of he coating components. including polydimethylsiloxane (PDMS), beta-cyclodextrin (beta-CD) and divinylbenzene (DVB) were investigated according to an orthogonal experimental design, using three polycyclic aromatic hydrocarbons (PAHs) and four polycyclic aromatic sulfur heterocycles (PASHs) as model analytes. Four kinds of stir bars coated with PDMS. PDMS/beta-CD, PDMS/DVB and PDMS/beta-CD/DVB were prepared and their extraction efficiencies for the target compounds were compared. It was demonstrated that PDMS/beta-CD/DVB-coated stir bar showed the best affinity to the studied compounds. The preparation reproducibility of PDMS/beta-CD/DVB-coated stir bar ranged from 3.2% to 15.2% (n = 6) in one batch, and 5.2% to 13.4% (n = 6) among batches. The "dumbbell-shaped" stir bar Could be used for about 40 times, which were 10 extractions more than a normal stir bar. The prepared PDMS/beta-CD/DVB-coated "dumbbell-shaped" stir bar was used for stir bar sorptive extraction (SBSE) of PAHs and PASHs and the desorbed solution was introduced into HPLC-UV for Subsequent analysis. The limits of detection of the proposed method for seven target analytes ranged from 0.007 to 0.103 mu g L-1, the relative standard deviations were in the range of 6.3-12.9% (n = 6, c = 40 mu g L-1), and the enrichment factors were 19-86. The proposed method was successfully applied to the analysis of seven target analytes in lake water and soil samples. (C) 2009 Elsevier B.V. All rights reserved.
源语言英语
页(从-至)75-82
页数8
期刊Analytica Chimica Acta
卷641
期1-2
DOI
出版状态已出版 - 8 5月 2009

基金资助

This work is financially supported by the National Nature Science Foundation of China (grant no. 20775057), the Science Fund for Creative Research Groups of NSFC (no. 20621502) and NCET-04-0658, MOE of China.

关键词

  • Stir bar sorptive extraction
  • Polydimethylsiloxane/beta-cyclodextrin/divinylbenzene coating Polycyclic aromatic hydrocarbons
  • Polycyclic aromatic sulfur heterocycles
  • High performance liquid chromatography-ultraviolet detector

收录

  • EI
  • Scopus
  • SCIE

学术指纹

探究 'Preparation of polydimethylsiloxane/β-cyclodextrin/divinylbenzene coated "dumbbell-shaped" stir bar and its application to the analysis of polycyclic aromatic hydrocarbons and polycyclic aromatic sulfur heterocycles compounds in lake water and soil by high performance liquid chromatography' 的科研主题。它们共同构成独一无二的学术指纹。

引用此