摘要
The liquid in transparent cylindrical vessel converges light, and the air above the liquid surface scatters the light. Light intensity through the liquid is much greater than that through the air above the liquid surface in CIS (Contact Image Sensor) fixed on the focus line of the liquid cylinder. The higher the liquid level, the more the number of sensor elements to accept the light with high intense. As a result, the real-time level of liquid can be detected by means of signal processing for sensor elements. This method is simple and reliable when the liquid level varies in the range of the height of CIS. We measured 18 liquid levels with approximate equal interval in 200 mm range. Experiment result shows that the mean level error is 0.185 mm and the maximum level error is 0.66 mm.