摘要
This paper describes the use of the drainage gradient method for assessing the relative inhibitory effectiveness of various reverse osmosis (RO) anti-scalants. Five different anti-scalants were selected for the examination of the drainage gradient method's feasibility for evaluating their relative inhibitory effectiveness. The results show that pH, Delta K-Ca (increase in cycles of concentration) and Langelier's saturation index (LSI) can be used as indicators and that Delta K-Ca( is the most suitable indicator. The sensitivities of the three indicators from greatest to least are: Delta K-Ca > LSI >> pH, with relative standard deviations (RSD) which are 38.39%, 14.22%, and 1.45%, respectively. The order of the scale suppression effectiveness of the five tested anti-scalants, based on the three judgment indicators, is D>E>B>C> A. (C) 2014 Elsevier B.V. All rights reserved.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 357-361 |
| 页数 | 5 |
| 期刊 | Desalination |
| 卷 | 344 |
| DOI | |
| 出版状态 | 已出版 - 1 7月 2014 |
关键词
- Drainage gradient
- Reverse osmosis
- Anti-scalant
- Evaluation method introduction
收录
- EI
- Scopus
- SCIE
学术指纹
探究 'The use of the drainage gradient method for evaluating reverse osmosis membrane anti-scalants' 的科研主题。它们共同构成独一无二的学术指纹。引用此