TY - GEN
T1 - Verification Experiment of Simulating the Effect of Quarantine Source on Isolated Switch
AU - Cheng, Lin
AU - Pan, Zhezhe
AU - Liu, Xiang
AU - Deng, Xiaoping
AU - Zhou, Hang
AU - Zhu, Yong
PY - 2019/4/12
Y1 - 2019/4/12
N2 - In order to simulate the actual scene of the harsh electromagnetic environment in the substation, and then study on electromagnetic compatibility testing of electronic instrument transformer, an isolated switch simulation source system is developed to promote the standardization of the original test based on the original isolation switch as a harassment source of the electronic instrument transformer electromagnetic compatibility test system. In this paper, the circuit breaker is used to control the opening and closing of the gap arc to simulate the operating of isolating switch, and the isolation switch simulation harassment source system is designed accordingly. Compared with the actual test results of the isolating switch, it is proved that the system can meet the test requirements, and the simulation harassment source system has good stability and high reliability. Therefore, the proposed isolation switch simulation harassment source electronic transformer immunity test can replace the current 'isolation switch sub-capacity of small current conditions under the electronic transformer immunity test' experiment and further promote the current electronic transformer performance testing of electromagnetic compatibility test standardization. © 2018 IEEE.
AB - In order to simulate the actual scene of the harsh electromagnetic environment in the substation, and then study on electromagnetic compatibility testing of electronic instrument transformer, an isolated switch simulation source system is developed to promote the standardization of the original test based on the original isolation switch as a harassment source of the electronic instrument transformer electromagnetic compatibility test system. In this paper, the circuit breaker is used to control the opening and closing of the gap arc to simulate the operating of isolating switch, and the isolation switch simulation harassment source system is designed accordingly. Compared with the actual test results of the isolating switch, it is proved that the system can meet the test requirements, and the simulation harassment source system has good stability and high reliability. Therefore, the proposed isolation switch simulation harassment source electronic transformer immunity test can replace the current 'isolation switch sub-capacity of small current conditions under the electronic transformer immunity test' experiment and further promote the current electronic transformer performance testing of electromagnetic compatibility test standardization. © 2018 IEEE.
KW - Electric circuit breakers
UR - https://openir.whu.edu.cn/AchievementDetail/EI_fdecb1c5-cc11-480d-9346-48632cf0add5
U2 - 10.1109/iicspi.2018.8690330
DO - 10.1109/iicspi.2018.8690330
M3 - Conference contribution
SN - 9781538655139
T3 - Proc. IEEE Int. Conf. Saf. Prod. Informatiz., IICSPI
SP - 219
EP - 222
BT - Proceedings of 2018 IEEE International Conference of Safety Produce Informatization, IICSPI 2018
PB - Institute of Electrical and Electronics Engineers Inc.
ER -